Home » News » Technical Support »
News Relevant information about Kvtester
-

What are the consequences of non-compliant short-circuit impedance?
2026-10-16What are the consequences of non-compliant short-circuit impedance? Short-circuit impedance is a critical technical parameter for a transformer; it is closely related to voltage variation, short-circuit current, and load distribution when transformers operate in parallel. "Non-compliant short-circuit impedance" generally refers to a significant deviation between the measured value and the… -

What are the differences between insulation resistance, absorption ratio, and polarization index?
2026-10-15What are the differences between insulation resistance, absorption ratio, and polarization index? In insulation testing for electrical equipment—such as transformers, motors, and cables—insulation resistance, absorption ratio, and polarization index are frequently measured. While all three provide insight into the condition of the equipment's insulation, they carry different meanings and focus… -

What is the purpose of a transformer load test?
2026-10-15What is the purpose of a transformer load test? A transformer load test is a key component of transformer performance testing. It is primarily used to measure parameters such as load loss and short-circuit impedance under conditions of rated frequency and specified current, thereby determining whether the transformer's windings and… -

What causes unstable results in transformer DC resistance tests?
2026-10-15What causes unstable results in transformer DC resistance tests? DC resistance testing is a crucial procedure for evaluating the condition of transformer windings, lead connections, and tap-changer contacts. During on-site testing, one may occasionally encounter issues such as resistance readings that remain unstable for extended periods, values that fluctuate, or… -

What are the respective functions of binary inputs and binary outputs in a relay protection tester?
2026-09-24What are the respective functions of binary inputs and binary outputs in a relay protection tester? The terms "binary input" (or "switch input") and "binary output" (or "switch output") frequently appear in the specifications of relay protection testers. When purchasing or using these testers, users often focus on voltage/current output… -

How to quickly troubleshoot a failure of the protection device to operate during relay protection testing?
2026-09-24How to quickly troubleshoot a failure of the protection device to operate during relay protection testing? Failure of the protection device to operate is a common issue encountered during field relay protection testing. Even though the test set outputs the required voltage, current, or fault quantities, the protection device may… -

Why does the required capacity of series resonant test equipment usually increase with cable length?
2026-09-18Why does the required capacity of series resonant test equipment usually increase with cable length? When selecting equipment for AC withstand voltage testing on cables, a common question arises: why do manufacturers specify different series resonant equipment configurations for cables of the same voltage rating (e.g., 10kV or 35kV) depending… -

How should 35kV cable series resonant withstand voltage test equipment be configured?
2026-09-18How should 35kV cable series resonant withstand voltage test equipment be configured? 35kV power cables are widely used in substations, renewable energy plants, industrial and mining enterprises, and power transmission and distribution projects. As cable length increases, so does the equivalent capacitance, placing higher demands on the current and capacity… -

How to Select AC Withstand Voltage Test Equipment for 10kV Cables?
2026-09-18How to Select AC Withstand Voltage Test Equipment for 10kV Cables? A Guide to Series Resonant System Selection 10kV power cables are widely used in industrial and mining enterprises, power distribution projects, new energy plants, and urban power supply systems. AC withstand voltage testing is frequently required during cable commissioning… -

What parameters must be provided to the manufacturer when purchasing series resonant withstand voltage test equipment?
2026-09-18What parameters must be provided to the manufacturer when purchasing series resonant withstand voltage test equipment? When purchasing series resonant withstand voltage test equipment, many users simply ask questions like, "What size equipment do I need for a 10kV cable?" or "How much does a 35kV series resonant system cost?"…




