Features and Advantages
1.Simultaneously measure and respectively display the typical decomposition products
2.High precision, good stability, minimum tested quantity can be low as 0.1µl/L
3.Fast testing speed, can finish within 1 minute
4.Fault diagnosis and suggestion function, data management function, gas flow rate can be regulated and displayed
5.Simple operation, intuitive interface, self-contained power supply, No need calibration within 1 year
6.Eco-friendly, little gas consumption: 200~300ml for each time measuring
7.Decomposition products: SO2, H2S ( CO, HF optional)
Parameter
| Decomposition products | H2S | 0 ~ 100 ppm (µL / L) ( standard ) ( not long-term than 200PPM) |
| SO2 | 0 ~ 100 ppm (µL / L) ( standard ) ( not long-term than 200PPM) | |
| CO | 0 ~ 500 ppm (µL / L) ( optional ) ( not over a long 1000PPM) |
| Resolution | 0.1 ppm (µL / L) | |
| Accuracy | SO2, H2S | 5 ~ 20 ± 1 ppm (µL / L) 20 ~ 100 ±3 ppm (µL / L) |
| CO | 5 ~ 50 ±3 ppm (µL / L) 50 ~ 200 ±10 ppm (µL / L) |
| The limit of detection | SO2 | ≤0.1 ppm (µL / L) |
| H2S | ≤0.1 ppm (µL / L) | |
| CO | ≤1 ppm (µL / L) |
| Repeatability | <± 2% | |
| Measurement time | about 3 minutes | |
| A sampling | built-in flow valve , electronic mass flow meter , 5 m sampling tube and pipe two meters out . | |
| sampling flow | 0.15 ~ 0.3 l / min | |
| Working temperature | -20 ℃ ~ + 50 ℃ | |
| sampling | quick connectors, PTFE tube extension , built-in electronic flow meter | |
| Operating temperature | -20 ℃ ~ 50 ℃ | |
| Power Source | AC and DC ; once fully charged can work continuously for eight hours , AC : 220V / 50Hz | |
| Display | Large color touch screen LCD display with a resolution of 800 × 480; | |
| Input | High sensitivity touch screen | |
| Output interface | USB 2.0; | |
| Storage | with a storage capacity of thousands of pieces of data , with automatic storage function , can also be manually store the current test data | |
| Volume weight | 320 × 270× 140 (mm) | |