CTA-1000C Portable
CT/PT Analyzer for
IEC Transformer Testing

  • CT ratioaccuracy ±0.05%,ratio range 1-40000
  • PT ratio accuracy ±0.2% for voltage transformer verification
  • Automatic test and evaluation in less than 2 minutes
  • CT ratioaccuracy ±0.05%,ratio range 1-40000
CT PT Test System
VT/CVT Analyzer
Protective Relay Tester

Request CTA-1000C Price

CTA-1000 Series CT Analyzer automatically determines all relevant current transformer values and compares the results with

    Working Voltage
    Rated Power
    Speed Range
    Max Peak Power (kW)
    Test Items
    Testing Input Electrical Parameters
    Testing Output Performance
    Low Voltage Start Test
    Load Start Test
    Vibration Test
    Temperature Rise Test
    Noise Test

    Why Choose CTA-1000C CT/PT Analyzer?

    Kvtester Electronics Technology Co., Ltd. is a leading and high-tech enterprise specializing in the R&D,
    manufacturing, and sales of power testing equipment and measurement instruments.
    • 01

      High Ratio Accuracy

      CT ratio accuracy reaches+0.05%, helping users verifymetering and protection CTs withconfidence
      5704279
      5704279
    • 02

      Automatic IEC/IEEE Evaluation

      The instrument automatically compares results with selected IEC and IEEE standards and provides quick pass/fail reference.
      11993008
      11993008
    • 03

      Fast and Safer Testing

      Most automatic tests can be completed in under 2 minutes, with maximum 180V test voltage for safer field operation.
      7275759
      7275759
    • 04

      Portable Pull-Box Design

      Lightweight structure below 10kg makes the CT/PT tester easy to carry for frequent on-site service work.
      11343455
      11343455

    CT Analyzer Working Principle and Test Flow

    Kvtester Electronics Technology Co., Ltd. is a leading and high-tech enterprise specializing in the R&D,
    manufacturing, and sales of power testing equipment and measurement instruments.
    • Connect CT/PT Terminals

      CT ratio accuracy reaches+0.05%, helping users verifymetering and protection CTs withconfidence
      01
    • Run Automatic Test

      CT ratio accuracy reaches+0.05%, helping users verifymetering and protection CTs withconfidence
      02
    • Generate Evaluation

      CT ratio accuracy reaches+0.05%, helping users verifymetering and protection CTs withconfidence
      03

    CTA-1000C
    Test Functions

    • CT ratioaccuracy ±0.05%,ratio range 1-40000
    • PT ratio accuracy ±0.2% for voltage transformer verification
    • Automatic test and evaluation in less than 2 minutes
    • CT ratioaccuracy ±0.05%,ratio range 1-40000
    • PT ratio accuracy ±0.2% for voltage transformer verification
    • Automatic test and evaluation in less than 2 minutes
    • CT ratioaccuracy ±0.05%,ratio range 1-40000
    DSC04233

    Application Scenarios

    • IMG_5516

      Power utility field testing

    • 按需定制

      Substation commissioning

    • 全方位支持

      CT/PT manufacturer production

    • 丰富项目经验

      Great Experience With Projects

      CTA-1000C CT/PT Tester Specifications

      Key technical parameters for purchasing engineers evaluating IEC transformer tester equipment.
      Product ModelCTA-1000C Portable CT/PT Analyzer
      Reference StandardsIEC60044-1, IEC60044-6, IEC61869-2-2012, IEEE related evaluation
      Output0–180Vrms, 12Arms, 36A peak value
      Voltage Accuracy±0.1%
      CT RatioRange 1–40000; accuracy ±0.05%
      PT RatioRange 1–40000; accuracy ±0.2%
      PhaseRange ±2min; accuracy 0.5min
      DC Resistance / Burden0–300Ω accuracy 0.2%±2mΩ; burden 0–1000VA accuracy 0.2%±0.02VA
      Power / EnvironmentAC110V±10% / AC220V±10%, 50/60Hz; -10℃~50℃, humidity ≤90%
      Dimensions & Weight365mm × 290mm × 153mm; weight <10kg

      Inquiry Workflow

      Simple process from technical requirements to quotation
      • 7544906

        Submit Test Requirements

        Share CT/PT type, ratio range, voltagelevel,
        standards and application site.
        01
        inquiry_shape
      • 3208369

        Get Model Confirmation

        KVTESTER confirms CTA-1000C configuration,
        accessories anddocumentation.
        02
        inquiry_shape
      • 2822667

        Receive Price & Datasheet

        Get quotation, datasheet, delivery time and support details for procurement.
        03
        inquiry_shape
      Looking for a Portable CT/PT Analyzer?

      The CTA-1000C portable CT/PT tester helps field engineers and calibration labs complete current transformer and voltage transformer tests faster, safer and with IEC-compliant reporting—without time-consuming manual calculations or high-voltage risks.