ZCHG-12 Automatic
Current Transformer
Test System for
Accuracy Calibration

  • Primary current: 5 A – 5000 A
  • Burden: 0 – 80 VA, continuously adjustable
  • Test method: Comparison Method
  • Test 12 CTs Within 4 Minutes
CT PT Test set
CT PT Test System
CT PT Calibration System

CT Test Set or Platform

ZCHG-12 is designed for automatic CT accuracy testing and error calibration. Operators only need to input transformer type, measurement range, precision class, capacity and power factor through the PC interface — the system completes testing, analysis, result management and certificate printing.

    Power Supply
    Type of the object
    User Type
    Product using occasion
    Applied voltage level of CT/PT/VT
    Primary current range of CT

    Why Choose ZCHG-12 CT PT Test System?

    Kvtester Electronics Technology Co., Ltd. is a leading and high-tech enterprise specializing in the R&D,
    manufacturing, and sales of power testing equipment and measurement instruments.
    • 01

      Test 12 CTs Within 4 Minutes

      With one-time wiring, ZCHG-12 can complete testing for up to 12 CTs within 4 minutes, making batch CT calibration faster and more efficient
      5704279
      5704279
    • 02

      Accuracy Test Under Any Burden

      The system adopts the comparison method to perform CT accuracy testing under any specified burden conditions.
      11993008
      11993008
    • 03

      Compliant with IEC/IEEE Standards

      ZCHG-12 meets IEC and IEEE testing standards, providing reliable reference for CT accuracy verification, calibration and quality control.
      7275759
      7275759
    • 04

      Error Prompt and Protection

      Provides real-time error prompts and provides overcurrent and overvoltage protection for safer operation.
      11343455
      11343455

    ZCHG-12 Working Principle and Test Flow

    Kvtester Electronics Technology Co., Ltd. is a leading and high-tech enterprise specializing in the R&D,
    manufacturing, and sales of power testing equipment and measurement instruments.
    • Connect 1–12 CTs

      Connect 1-12 current transformers to the ZCHG-12 test system according to the test requirements. The system supports batch testing with one-time wiring, reducing repeated connection work and improving testing efficiency.
      01
    • Input CT Parameters

      Operators enter the current transformer type, measurement range, accuracy class, capacity and power factor through the PC-based virtual interface.
      02
    • Run Automatic Testing

      The system automatically controls measurement, current/voltage adjustment and load switching, then performs CT accuracy test, error calibration, demagnetization, inter-turn insulation test and polarity check.
      03
    • Analyze Results and Generate Reports

      ZCHG-12 automatically analyzes and calculates the test results, manages the data, and outputs test records or Word certificates according to user requirements.
      04

    ZCHG-12
    Test Functions

    • CT Accuracy Test: Automatically performs current transformer accuracy testing and error calibration
    • CT Demagnetization Function: Supports both open-circuit and closed-circuit demagnetization for current transformers
    • CT Inter-turn Insulation Test: Checks the inter-turn insulation condition of current transformers during the verification process
    • CT Polarity Check: Verifies CT polarity to ensure correct wiring and reliable test results
    CT PT Test System 1

    Application Scenarios

    • Cover of current transformer factory

      Current Transformer Factories

    • Cover of switchgear

      Switchgear Manufacturers

    • 第三方检测公司

      Testing Companies / Institutions

      ZCHG-12 CT PT Test System Specifications

      Key technical parameters for purchasing engineers evaluating IEC transformer tester equipment.
      System Technical Parameters
      Maximum Number of CTs Tested 12 CTs at one time
      Maximum Number of PTs Tested  6 PTs at one time
      Input Voltage AC 400V, 50Hz, Three-phase four-wire
      Input Current AC 0~50A
      Rated Capacity 10~30kVA
      Test Functions CT Accuracy Test, CT Demagnetization Function, CT Inter-turn Insulation Test, CT Polarity check
      Test method Computer controlled automatic test
      CT Demagnetization Function Supports open-circuit and closed-circuit demagnetization
      Protection Functions Provided overcurrent & overvoltage protection
      CT Rated Primary Current 5~5000A
      CT Rated Secondary Current 1A, 5A
      Standard CT accuracy 0.01S class
      Standards Compliance IEC61869-1, IEC61869-2

       

      Inquiry Workflow

      Simple process from technical requirements to quotation
      • 7544906

        Submit Test Requirements

        Share CT/PT type, ratio range, voltage level,
        class and standards.
        01
        inquiry_shape
      • 3208369

        Get Model Confirmation

        KVTESTER confirms ZCHG-12 configuration,
        accessories and documentation.
        02
        inquiry_shape
      • 2822667

        Receive Price & Datasheet

        Get quotation, datasheet, delivery time and support details for procurement.
        03
        inquiry_shape
      Looking for an Automatic CT/PT Test System?

      ZCHG-12 is designed for automatic CT accuracy testing and error calibration. Operators only need to input transformer type, measurement range, precision class, capacity and power factor through the PC interface — the system completes testing, analysis, result management and certificate printing.