Home » News » Technical Support »
News Relevant information about Kvtester
-
The application of smart grid in Power Technology
2019-10-30Abstract: with the rapid development of China's power industry, smart grid has become an important part of the development of the power industry. Firstly, the smart grid is described; secondly, the characteristics of smart grid technology are analyzed; finally, the application of smart grid in power technology and power system… -
Do not do these ten things when installing the transformer
2019-10-29Transformer is the heart of the power supply and distribution system, which transforms high-voltage power into low-voltage power for daily use. Transformer installation is also the most important part of the whole power installation project. To ensure the quality of transformer installation is very important for the stable operation of… -
State grid displays "Ai + power" application scenario AI to
2019-10-28 -
Characteristics of dielectric strength tester for insulating
2019-10-26Insulating oil dielectric strength tester is an advanced instrument and equipment designed and developed in accordance with the requirements of national standards. It has many advantages, beautiful appearance and convenient operation. Today, it is welcomed by users to introduce the function of insulating oil dielectric strength tester. 1. The… -
How to choose frequency conversion series resonance?
2019-10-25How to choose frequency conversion series resonance? Nowadays, a lot of power industry related manufacturers will use series resonance tester, so we must compare and inspect the market of series resonance sales. Here, Zhizhuo measurement and control recommends you to choose famous large factories, so that they… -
How to select high voltage circuit breaker
2019-10-24I. selection of high voltage circuit breaker - type and type The type and type of high-voltage circuit breaker shall be selected according to the installation location, environment and service conditions of the circuit breaker. Vacuum circuit breaker has been widely used in 35kV and below power… -
Some thoughts on dealing with transformer short circuit acci
2019-10-231. Inspection of iron core and clamp The core of the transformer shall have sufficient mechanical strength. The mechanical strength of the iron core is guaranteed by the strength of all clamping parts on the iron core and their connecting parts. When the winding generates electric power,… -
Basic knowledge of Substation
2019-10-22Substation Power is transmitted through a power transformer. In the power system, the process of transforming the voltage from low level to high level (step-up) or from high level to low level (step-down) through certain equipment. Generally, the rated voltage of generator in power system is below (15-20) kV.… -
How to solve the problem that the test results of transforme
2019-10-21Wuhan Zhizhuo measurement and Control Technology Co., Ltd. solves the problem that the test results of transformer tester cannot be saved Problem Description: The analyzer startup process is normal, the test process is normal, and the test results are normal, but the test results cannot be saved, nor can… -
What are the standards of insulator zero value tester
2019-10-19In the ordinary work, the power workers often need to test the zero value of the insulator to test the voltage distribution value of the insulator string, so they need to use the insulator zero value tester. In the process of testing, the equipment has certain standards for the test…