The working principle and product application of a fully automatic capacitance and inductance tester
2023-08-08Fully automatic capacitance and inductance tester, abbreviated as capacitance and inductance tester. The fully automatic capacitance and inductance tester adopts a bridge circuit structure, with standard capacitors and the tested electrical container as the two arms of the bridge circuit. When measuring the capacitance value of the capacitor, close the… -
The reason why the DC high-voltage generator cannot add high voltage
2023-07-31There may be several reasons why the DC high-voltage generator cannot add high voltage:1. Power issue:The DC high-voltage generator requires a stable and reliable power supply to operate normally. If the power supply voltage is unstable, fluctuates significantly, or the power supply current is insufficient, it may cause the DC… -
Analysis on the Causes of Transformer Oil Dielectric Loss Exceeding the Standard
2023-07-27Dielectric loss refers to the conductivity loss and polarization loss generated by transformer oil under the action of alternating power plants. This type of loss can lead to a decrease in insulation strength and heat transfer performance, ultimately leading to problems such as overheating, damage, and breakdown of the transformer.… -
Safety precautions for using a transformer comprehensive tester
2023-07-26CTP-1000C variable frequency transformer comprehensive tester is a new generation of innovative CT and PT testing instrument developed on the basis of the traditional transformer volt ampere characteristic ratio polarity comprehensive tester based on the Pressure regulator, voltage booster and current riser, and after extensive listening to user opinions, a… -
Common faults and solutions of transformer power analyzer
2023-07-25ZC-201A Transformer Power Analyzer can measure the no-load current, no-load loss, short-circuit voltage, and short-circuit (load) loss of transformers. Harmonic testing can be conducted to analyze up to 31 harmonics. The instrument automatically switches range internally, allowing for a wide range of voltage and current measurements, and simple wiring. When… -
Functional characteristics of transformer capacity and no-load load tester
2023-07-24ZC-202B Transformer Capacity and Empty Load Tester is a new type of instrument developed and designed by our company specifically for the problem of poor power users evading basic electricity bills and increasing capacity without authorization. It is a high-precision instrument used for measuring characteristic parameters such as transformer capacity,… -
The working principle and product characteristics of transformer ratio tester
2023-07-21The transformer ratio tester mainly performs turn to turn ratio or voltage ratio testing, which can overcome the shortcomings of traditional transformer ratio bridge testing. Therefore, for this instrument, its working principle and product characteristics, let me take you to understand.Working principle:The working principle of a transformer ratio tester is… -
Analysis of Oil Leakage Fault in Oil Immersed Transformers
2023-07-20What is the cause of oil leakage in oil immersed transformers? Next, the editor will give you a brief introduction.1. Welding qualityThe shell of an oil immersed transformer is a combination of welded and connected steel plates. Due to the long weld seam and numerous welded joints, high requirements are… -
Fault Diagnosis Method for Oil Immersed Transformers
2023-07-19The fault diagnosis method for oil immersed transformers is to analyze the collected transformer fault information and determine the type of transformer fault based on the data analysis results. During this process, the accuracy of the collected information plays a crucial role in the accuracy of fault diagnosis. There are… -
What are the reasons for partial discharge in transformers?
2023-07-18The degradation of transformer insulation is often the result of a combination of multiple factors, not a single factor. Partial discharge is not only the cause of insulation degradation, but also a precursor and manifestation of insulation degradation. The direct causes of partial discharge in transformers usually include:① There are…