How to regularly calibrate the short-circuit impedance tester?

:2024-03-13 10:54:49:

Regular calibration of the short-circuit impedance tester is an important step to ensure its accuracy and reliability. Here are some recommended periodic calibration methods:

1. Reference standard calibration: Use a high-precision reference standard to calibrate the short-circuit impedance tester. The reference standard can be high-precision components such as resistors, inductors, or capacitors. By comparing the short-circuit impedance tester with a reference standard, its accuracy and error can be evaluated.

2. Comparative measurement: Use multiple short-circuit impedance testers of the same model for comparative measurement. By comparing the measurement results between different instruments, the accuracy and consistency of each instrument can be evaluated. This method requires ensuring that all instruments participating in the comparison undergo the same calibration and testing conditions.

3. Regular inspection: Send the short-circuit impedance tester to a professional calibration institution for calibration on a regular basis. These institutions typically have higher-level calibration equipment and technology that can comprehensively calibrate and evaluate instruments. By sending the instrument for inspection, it can be ensured that it complies with relevant standards and specifications, and calibration certificates and reports can be obtained.

Regardless of the calibration method chosen, the following points should be noted:

① Calibration should be carried out under normal operating conditions of the instrument, including factors such as ambient temperature, humidity, and power stability.

② Before calibration, the instrument should be thoroughly preheated and stabilized to eliminate internal temperature drift and mechanical stress.

③ During the calibration process, it is necessary to strictly follow the calibration procedures and operating procedures to avoid operational errors and errors.

④ The calibration results should be recorded in detail, including calibration date, calibration method, calibration results, and calibration personnel information, for subsequent traceability and analysis.

In summary, regular calibration is an important measure to ensure the accuracy and reliability of short-circuit impedance testers. By selecting appropriate calibration methods and following calibration procedures, the instrument can ensure long-term stable operation and provide accurate measurement results to users.

ZC-204B.jpg

ZC-204B Transformer short-circuit impedance tester has the internal adjustable power output and do not need the outside pressure regulator, only need to provide 220V power supply can be tested, especially suitable for the field of 110kV level and above the main transformer for low voltage short circuit impedance measurement.

Kvtester Electronics Technology Co.,Ltd. is a high-tech enterprise specializing in power testing, testing, research and development, production, and sales of testing equipment. It has been engaged in the electrical testing industry for many years, and its products are of high quality. We welcome customers to come and purchase. Service hotline: 0086-27-81778799, to learn more, visit the official website: www.kvtester.com