What are the precautions for using a live cable identification device
2023-06-01What are the precautions for using a live cable identification device1、 Avoid direct contact with metal rods with handsWhen using a live cable identification device, we first need to connect the metal rod of the live cable identification device to the metal protective layer or metal shield of the faulty… -

The causes and solutions of common faults in power transformers
2023-05-31Power transformer is a static power equipment that changes the magnitude of AC voltage, and is one of the core equipment in the power system. In the process of energy transmission and distribution, power transformer is the core of energy conversion and transmission, and is a necessary path for various… -

What precautions should be taken during the power frequency withstand voltage operation test?
2023-05-24Precautions for power frequency withstand voltage test:1. Testers should divide their responsibilities, set a safe distance at the test site, carefully inspect the grounding of the tested object and the test transformer, and assign dedicated personnel to monitor safety and observe the status of the tested object.2. The main parts… -

Protective measures for power cable faults
2023-05-22Electric wires and cables play a crucial role in the infrastructure construction of our country. Power cables are commonly used in urban underground power grids, power station outgoing lines, internal power supply of industrial and mining enterprises, and underwater transmission lines crossing rivers and seawater. They are composed of four… -

How to quickly find the fault point of the cable
2023-05-22With the increase of cable routes, the morning impact of cable faults on power supply reliability is increasing. Therefore, quickly and accurately detecting the location of fault points is of great significance to ensure the timely repair of faulty cables. The detection method for cable faults depends on the nature… -

Multiple Wiring Methods for Grounding Resistance Testers
2023-05-17There are usually several measurement methods for grounding resistance testers: two wire method, three wire method, four wire method, single clamp method, and double clamp method, each with its own characteristics. In actual measurement, the correct method should be chosen as much as possible to ensure accurate measurement results.1. Two… -

Reasons and solutions for inaccurate measurement of grounding resistance readings
2023-05-16Grounding resistance is an important parameter used to measure whether the grounding state is good. It is the resistance encountered when the current flows from the grounding device to the ground and then flows through the ground to another grounding body or spreads to a distance. It includes the resistance… -

Precautions for operating the DC resistance tester
2023-05-15The DC resistance tester is mainly used to test the DC resistance value of high-voltage electrical equipment such as power transformers. It has many characteristics such as fast testing speed, high accuracy, convenience, flexibility, and portability. It has always been a favorite equipment for many power workers, and there are… -

What are the methods to eliminate the interference sources when measuring partial discharge of transformer?
2023-05-10The interference sources during the measurement of partial discharge of transformer include the interference of power supply network, interference of various electromagnetic field radiation, poor contact of test circuit, corona at various parts and internal discharge of test equipment, interference of earthing system, and interference of suspended discharge of metal… -

What are the precautions for no-load testing of transformers?
2023-05-09The main purpose of transformer no-load test is to measure the no-load current and no-load loss, analyze their variation patterns, discover local or overall defects in the magnetic circuit, and discover winding defects. The precautions for transformer no-load test include:1. The test should be conducted at the rated tap, and…